SCENAR NT |
|
|
|
|
|
 |
|
|
|
|
|

It is a line of professional devices with a great medical potential,
reliability in operation, and a capability to display a large amount of information. The
devices are designed for professional application by general practitioners in outpatient
departments, ambulance, as well as at home.
"SCENAR-1-NT" version 01
Specifications:
- influencing impulse frequency is selected in the range from 15 to 350 Hz;
- “frequency modulation” mode, the range is 30 to 120 Hz;
- intermittent pulse trains with duration from 1 to 5 sec with the time gap of 1 sec;
- 4 modes of influencing pulse waveform modification (“damping”);
- variable pulse waveform (variable damping – var “damping”);
- “intensive therapy” mode (influencing by impulse packets, the number of impulses in
a packet is from 1 to 8);
- duration of gaps (including variable gaps) between the impulses in each packet can be
changed;
- combined modulation mode (“swing”);
- several modes of time-dosed high-amplitude influence (a single packet of from 1 to 8
high amplitude impulses) (“like a bee sting” – BEE mode);
- 2 screening modes; the mode of acupuncture points electroconductivity measuring at
alternating current;
- two algorithms of influence dosing;
- graphic display of the current reaction dynamics and velocity of its change;
- a special power decreasing mode for overly sensitive individuals and for treatment of
mucous membranes and open wounds;
- data display on a graphic LCD with backlight;
- up to 5 different programs can be saved;
- built-in stop-watch.
"SCENAR-1-NT" version 02
Three modifications of the version are available (see the summary table of
parameters).
Specifications:
- influencing impulse frequency is selected in the range from 15 to 350 Hz;
- “frequency modulation” mode, the range is 30 to 120 Hz;
- intermittent pulse trains with duration from 1 to 5 sec with the time gap of 1 sec;
- 4 modes of influencing pulse waveform modification (“damping”);
- the mode of variable pulse waveform (variable damping – var);
- "intensive therapy" mode (influencing by impulse packets, the number of
impulses in a packet is from 1 to 8);
- duration of gaps (including variable gaps) between the impulses in each packet can be
changed (“Z” submode);
- combined modulation mode (“swing”);
- 1 screening mode;
- two algorithms of influence dosing;
- a special power decreasing mode for overly sensitive individuals and for treatment of
mucous membranes and open wounds;
- data display on a graphic LCD with backlight;
- up to 5 different programs can be saved;
- built-in stop-watch.
"SCENAR-1-NT" version 03
Specifications:
- 4 influencing impulse frequencies 15, 60, 120 and 350 Hz;
- “frequency modulation” mode, the range is 30 to 120 Hz;
- intermittent pulse trains with duration of 3 sec and the time gap of 1 sec;
- one algorithm of influence dosing;
- graphic display of the current reaction dynamics and velocity of its change;
- data display on a graphic LCD with backlight.
"SCENAR-2-NT"
Specifications:
- two influencing impulse frequencies 60 and 120 Hz;
- “frequency modulation” mode, the range is 30 to 120 Hz;
- saw-tooth amplitude modulation;
- one algorithm of influence dosing;
- capability to estimate reaction values and reaction coefficient according to the LED
indicators states;
|
|
|
|
|
|
 |
|
|
|
|
|
The summary table of parameters
| Device parameters, versions |
SCENAR-
2-NT |
SCENAR-1-NT |
| 03 |
02
(Variant 3)
|
02
(Variant 2)
|
02
(Variant 1) |
01 |
Diagnostics:
EPD |
- |
- |
- |
- |
- |
+ |
| IDM |
- |
Integral
dose and null |
Integral
dose and null
|
Integral dose and null. Differential dose |
Integral dose and null. Differential dose |
Integral dose and null. Differential dose |
| Screening |
- |
- |
- |
- |
1 modes |
2 modes
|
| Dose indication |
Sound |
Sound and symbolic |
Sound and symbolic |
Sound and symbolic |
Sound and symbolic |
Sound and symbolic |
| Damping |
- |
- |
4 constant modes,
1 variable mode |
4 constant modes,
1 variable mode |
4 constant modes,
1 variable mode |
4 constant modes,
1 variable
mode |
| Amplitude modulation |
Saw-tooth |
“3 : 1” |
“1 : 1”, “2 : 1”, “3 : 1”, “4 : 1”, “5 : 1” |
“1 : 1”, “2 : 1”, “3 : 1”, “4 : 1”, “5 : 1” |
“1 : 1”, “2 : 1”, “3 : 1”, “4 : 1”, “5 : 1” |
“1 : 1”, “2 : 1”, “3 : 1”, “4 : 1”, “5 : 1”, BEE |
| Frequency modulation |
30 - 120 Hz, cycle - 8 sec |
30 - 120 Hz, cycle - 8 sec |
30 - 120 Hz, cycle - 8sec |
30 - 120 Hz, cycle - 8sec, swing |
30 - 120 Hz, cycle - 8sec, swing |
30 - 120 Hz, cycle - 8sec, swing |
| Influencing impulse frequencies |
60, 120 Hz |
15, 60, 120, 350 Hz |
15…350 Hz |
15…350 Hz |
15…350 Hz |
15…350 Hz
|
| Intensity (the number of impulses in a packet) |
1 |
1 |
1 … 8 |
1 … 8 |
1 … 8 |
1 … 8
|
| The duration of gaps between impulses in a packet - Z |
-
|
- |
200 … 1600
µsec |
200 … 1600
µsec |
200 … 1600
µsec |
200 … 1600
µsec |
| Power Influence |
10 … 250
units |
1 … 250
units |
1 … 250
units |
1 … 250
units |
1 … 250
units. |
1 … 250
units. |
| Indicator |
Light-emitting diodes |
Graphic LCD with backlight |
Graphic LCD with backlight |
Graphic LCD with backlight |
Graphic LCD with backlight |
Graphic LCD with backlight |
| Input of personal sets of parameters |
- |
- |
Up to 5 sets are saved. |
Up to 5 sets are saved. |
Up to 5 sets are saved |
Up to 5 sets are saved. |
|
|
|
|
|
|
 |